Ignition Cable: Testing and Inspection
1. REMOVE AIR CLEANER CAP AND MAF METER ASSEMBLY2. DISCONNECT HIGH-TENSION CORDS FROM SPARK PLUGS
- Disconnect the high-tension cords at the rubber boot.
- DO NOT pull on the cords.
NOTICE: Pulling on or bending the cords may damage the conductor inside.
3. DISCONNECT HIGH-TENSION CORDS FROM IGNITION COILS
- Using a screwdriver, lift up the lock claw and disconnect the holder from the ignition coils.
- Disconnect the high-tension cord at the grommet.
- DO NOT pull on the cord.
NOTICE:
- Pulling on or bending the cords may damage the conductor inside.
- Do not wipe any of the oil from the grommet after the high-tension cord is disconnected.
4. INSPECT HIGH-TENSION CORD RESISTANCE
- Using an ohmmeter, measure the resistance.
Maximum resistance: 25 ohms per cord
- If the resistance is greater than the maximum, check the terminals.
- If necessary, replace the high-tension cord.
5. RECONNECT HIGH-TENSION CORDS TO IGNITION COILS
- Assemble the holder and grommet.
- Align the spline of the ignition coil with the spline of the holder and push in the cord.
NOTICE: Check that the holder is correctly installed to the grommet and distributor cap as shown in the illustration.
- Check that the lock claw of the holder is engaged by lightly pulling the holder.
6. RECONNECT HIGH-TENSION CORDS TO SPARK PLUGS
7. REINSTALL AIR CLEANER CAP AND MAF METER ASSEMBLY