O/D Main Switch & O/D Off Indicator Light Circuit
O/D Main Switch & O/D Off Indicator Light CircuitCIRCUIT DESCRIPTION
The O/D main switch contacts go open when the switch is pushed in and go closed when it is pushed once again. In O/d main switch OFF position, the O/D OFF indicator lights up, and the ECM prohibits shifting to O/D.
WIRING DIAGRAM
(*) O/D Main Switch
Contacts go open witch switch pushed in.
Contacts go closed witch switch pushed once again.
INSPECTION PROCEDURES
O/D OFF indicator light does not light up.
O/D OFF indicator light remains ON.