Oxygen Sensor: Testing and Inspection
HEATED OXYGEN SENSORS INSPECTIONINSPECT HEATER RESISTANCE OF HEATED OXYGEN SENSOR
- Using an ohmmeter, measure the resistance between the terminals +B and HT.
Resistance: At 20°C (68°F): 11 - 16 ohm
- If the resistance is not as specified, replace the heated oxygen sensor.
HINT: Use a new gasket.
Torque: 20 N.m (14 ft.lb.)