Off-Vehicle Inspection
INSPECT IAC VALVE OPERATION- Connect the positive (+) lead from the battery to terminal -B and negative (-) lead to terminal RSC, and check that the valve is closed.
- Connect the positive (+) lead from the battery to terminal +B and negative (-) lead to terminal RSO, and check that the valve is open.