Service Hints

D16 DOOR LOCK CONTROL ECU
2-Ground: Always Approx. 12 Volts
11-Ground: Always continuity
8-Ground: Approx. 12 Volts with Ignition SW at ON position
7, 14-Ground: Continuity with Door opened
5-Ground: Approx. 12 Volts with Ignition SW ON and stays at 12 Volts for 60 Seconds after the Ignition SW is Turned OFF,
But if a Door is opened in this 60 Seconds period, voltage will drop to 0 Volts

D14, D15 DOOR COURTESY SW
1-Ground: Continuity with Door opened

P 4 POWER WINDOW CONTROL SW RH
4-GROUND: Approx. 12 Volts with Ignition SW ON and stays at 12 Volts for 60 Seconds after the Ignition SW is Turned OFF,
But if a Door is opened in this 60 Seconds period, Voltage will drop to 0 Volts

P 5 POWER WINDOW MASTER SW
6-Ground: Always continuity
9-Ground: Approx. 12 Volts with Ignition SW ON and stay at 12 Volts for 60 Seconds after the Ignition SW is Turned OFF,
But if a Door is opened in this 60 Seconds period, voltage will drop to 0 Volts
3-Ground: Approx. 12 Volts with Ignition SW at ON position and master SW at Up position
4-Ground: Approx. 12 Volts with Ignition SW at ON position and master SW at Down or Auto Down position

WINDOW LOCK SW
Open with Window Lock SW at Lock position