Power Window
I15-A, I16-B INTEGRATION RELAY11-GROUND: Always Approx. 12 Volts
6-GROUND: Approx. 12 Volts with Ignition SW at ON position
A-5-GROUND: Continuity with Front LH Door opened
POWER RELAY
2-1: Closed with Ignition SW ON and stays at 12 Volts for 60 seconds after the Ignition SW is turned OFF,
But if a Door is opened in this 60 seconds period, voltage will drop to 0 Volts
D16 DOOR COURTESY SW FRONT LH
1-GROUND: Continuity with Door opened
P 4 POWER WINDOW CONTROL SW FRONT RH
5-GROUND: Approx. 12 Volts with Ignition SW ON and stays at 12 Volts for 60 seconds after the Ignition SW is turned OFF,
But if a Door is opened in this 60 Seconds period, voltage will drop to 0 Volts
P 5, P 6 POWER WINDOW CONTROL SW REAR LH, RH
5-GROUND: Approx. 12 Volts with Ignition SW ON and stays at 12 Volts for 60 seconds after the Ignition SW is turned OFF,
But if a Door is opened in this 60 Seconds period, voltage will drop to 0 Volts
P 7 POWER WINDOW MASTER SW
2-GROUND: Always continuity
8-GROUND: Approx. 12 Volts with Ignition SW ON and stays at 12 Volts for 60 seconds after the Ignition SW is turned OFF, but if a Door is opened in this 60 seconds period, voltage will drop to 0 Volts
6-GROUND: Approx. 12 Volts with Ignition SW at ON position and master SW at UP position
13-GROUND: Approx. 12 Volts with Ignition SW at ON position and master SW at DOWN or AUTO DOWN position
WINDOW LOCK SW
Open with Window Lock SW at LOCK position