Oxygen Sensor: Testing and Inspection
HEATED OXYGEN SENSORS INSPECTION
(Bank 1, Sensor 1, Bank 1 Sensor 2)
INSPECT HEATER RESISTANCE OF HEATED OXYGEN SENSORS
(a) Disconnect the oxygen sensor connector.
Bank 1 Sensor 1:
Bank 1 Sensor 2:
(b) Using an ohmmeter. measure the resistance between the terminals +B and HT.
Resistance: At 20°C (68°F): 11 - 16 ohms
If the resistance is not as specified, replace the sensor.
Torque: 20 N.m (200 kgf.cm, 14 ft.lbf)
(c) Reconnect the oxygen sensor connector.