Removal and Installation
Starter Motor (5VZ-FE):
REMOVAL
REMOVE STARTER
1. Disconnect the starter connector.
2. Remove the nut and disconnect the starter wire.
Torque: 8.8 N.m (90 kg.cm, 70 in.lb)
3. Remove the 2 bolts and starter.
Torque: 39 N.m (400 kg.cm, 29 ft.lb)
INSTALLATION
Installation is in the reverse order of removal.