Operation CHARM: Car repair manuals for everyone.

Throttle Position Sensor: Specifications

Between Terminals Measured Resistance
At Clearance: 0 mm (0 in.) VTA - E2 0.2 - 5.7 Kilo Ohms (K ohms)
0.57 mm (0.022 in.) IDL - E2 2.3 K ohms or less
0.74 mm (0.029 in.) IDL - E2 Infinity
Throttle Fully Opened VTA - E2 2.0 - 10.2 Kilo Ohms (K ohms)
At all Times VC - E2 2.5 - 5.9 Kilo Ohms (K ohms)