Service Hints
I15 (A), I16 (B) INTEGRATION RELAY11-GROUND: Always approx. 12 Volts
6-GROUND: Approx. 12 Volts with ignition SW at ON position
(A) 5-GROUND: Continuity with front LH door opened
POWER RELAY [DRIVER SIDE J/B]
2-1: Closed with ignition SW ON and stays at 12 Voltsfor 60 seconds after the ignition SW is turned OFF, but it a door is opened in this 60 seconds period, voltage will drop to 0 Volts
D16 DOOR COURTESY SW FRONT LH
1-GROUND: Continuity with door opened
P 4 POWER WINDOW CONTROL SW FRONT RH
4-GROUND: Approx. 12 Volts with ignition SW ON and stays at 12 Volts for 60 seconds after the ignition SW is turned OFF, but if a door is opened in this 60 seconds period, voltage will drop to 0 Volts
P 5, P 6 POWER WINDOW CONTROL SW REAR LH, RH
4-GROUND: Approx. 12 Volts with ignition SW ON and stays at 12 Volts for 60 seconds after the ignition SW is turned OFF, but if a door is opened in this 60 seconds period, voltage will drop to 0 Volts
P 7 POWER WINDOW MASTER SW
3-GROUND: Always continuity
10-GROUND: Approx. 12 Volts with ignition SW ON and stays at 12 Volts for 60 seconds after the ignition SW is turned OFF, but if a door is opened in this 60 seconds period, voltage will drop to 0 Volts
1-GROUND: Approx. 12 Volts with ignition SW at ON position and master SW at UP position
5-GROUND: Approx. 12 Volts with ignition SW at ON position and master SW at DOWN or AUTO DOWN position
WINDOW LOCK SW
Open with window lock SW at LOCK position