Power Window

With the ignition SW turned ON, current flows through the GAUGE fuse to TERMINAL 7 of the integration relay to TERMINAL (A) 6 to TERMINAL 1 of the power relay to TERMINAL 2 to GROUND, which activates the relay, and the current flowing to TERMINAL 5 of the relay from the POWER fuse flows to TERMINAL 3 of the relay to TERMINAL 9 of the power window master SW.

1. MANUAL OPERATION (FRONT DOOR LH WINDOW)
With the ignition SW turned ON and with the power window master SW (Front LH) in UP position, the current flowing from TERMINAL 9 of the power window master SW flows to TERMINAL 3 of the master SW to TERMINAL 1 of the power window motor to TERMINAL 2 to TERMINAL 4 of the master SW to TERMINAL 1 to GROUND and causes the power window motor to rotate in the up direction, The window ascends only while the SW is being pushed.

In down operation, the current flowing from TERMINAL 9 of the power window master SW flows to TERMINAL 4 of the master SW to TERMINAL 2 of the power window motor to TERMINAL 1 to TERMINAL 3 of the master SW to TERMINAL 1 to GROUND, flowing in the opposite direction to manual up operation and causing the motor to rotate in reverse, opening the window.

2. AUTO DOWN OPERATION (FRONT DOOR LH WINDOW)
When the driver's window SW is pushed strongly to the down side, the current flowing to TERMINAL 9 of the power window master SW flows to the down contact point and auto down contact point of the driver's SW.

This activates the relay (Down side) inside the power window master SW and the hold circuit is activated simultaneously, so the relay (Down side) remains activated even when the SW is released.

Current flows at this time from TERMINAL 9 of the power window master SW to TERMINAL 4 to TERMINAL 2 of the power window motor to TERMINAL 1 to TERMINAL 3 of the power window master SW to TERMINAL 1 to GROUND, so the motor continues to operate until the driver's window is fully open.

When the driver's window is fully open, the hold circuit goes OFF and the relay (Down side) also turns OFF. As a result, the current flowing from TERMINAL 9 of the power window master SW to TERMINAL 4 is cut OFF, so the power window motor and auto down operation stop.

When the driver's SW is pulled to the up side during auto down operation, the hold circuit is turned OFF, so the current flowing from TERMINAL 9 of the power window master SW to TERMINAL 4 is cut OFF, and the power window motor stops. If the SW remains pulled up, the relay (Up side) is activated, and current flows from TERMINAL 9 of the power window master SW to TERMINAL 3 to TERMINAL 1 of the power window motor to TERMINAL 2 to TERMINAL 4 of the master SW to TERMINAL 1 to GROUND. Accordingly, the power window motor rotates in the up direction and manual up operation occurs while the SW is pulled up.

3. MANUAL OPERATION (FRONT DOOR RH WINDOW)
With the power window control SW front RH pulled to the up side, the current flowing from TERMINAL 4 of the power window control SW flows to TERMINAL 3 of the power window control SW to TERMINAL 2 of the power window motor to TERMINAL 1 to TERMINAL 1 of the power window control SW to TERMINAL 2 to TERMINAL 10 of the master SW to TERMINAL 1 to GROUND and causes the power window motor front RH to rotate in the up direction. The up operation continues only while the power window SW is pulled to the up side. When the window descends, the current flowing to the motor flows in the opposite direction, from TERMINAL 1 to TERMINAL 2, and the motor rotates in reverse. When the window lock SW is pushed to the lock side, the ground circuit to the front RH window becomes open.

As a result, even if Open/Close operation of the front RH window is attempted, the current from TERMINAL 1 of the power window master SW is not grounded. so the motor does not rotate, therefore the front RH window can not be operated. This is how the window lock function operates.

4. KEY OFF POWER WINDOW OPERATION
With the ignition SW turned from ON to OFF, the integration relay operates and current flows from the DOOR fuse to TERMINAL (A) 20 of the integration relay to TERMINAL (A) 6 to TERMINAL 1 of the power relay to TERMINAL 2 to GROUND for about 43 seconds. In the same way as normal operation, the current flows from the POWER fuse to TERMINAL 5 of the power relay to TERMINAL 3 to TERMINAL 9 of the power window master SW and TERMINAL 4 of the power window control SW front RH. As a result, this relay is still activated for about 43 seconds after the ignition SW is turned OFF, allowing the open/close operation of the power window. Also, by opening the front doors (Door open detection SW ON) within about 43 seconds after turning the ignition SW to OFF, a signal is input to TERMINAL 5 or 4 of the integration relay. As a result, the relay is turned OFF. and open/close movement of the power window stops.