Power Locks: Description and Operation

Current always flows to TERMINAL (B) 11 of the integration relay through the POWER fuse.

1. MANUAL LOCK OPERATION
To push the door lock control SW or door key lock and unlock SW to LOCK position, a lock signal is input to TERMINAL (B) 5 of the integration relay and causes the relay to function. Current flows from TERMINAL (B) 11 of the relay to TERMINAL (B) 2 to TERMINALS 3 (LH), 2 (RH) of the door lock motors to TERMINALS 7 (LH), 6 (RH) to TERMINAL (B) 3 of the relay to TERMINAL (A) 7 to GROUND and the door lock motor causes the door to lock.

2. MANUAL UNLOCK OPERATION
To push the door lock control SW or door key lock and unlock SW to UNLOCK position, an unlock signal is input to TERMINAL (B) 6 of the integration relay and causes the relay to function. Current flows from TERMINAL (B) 11 of the relay to TERMINAL (B) 3 to TERMINALS 7 (LH), 6 (RH) of the door lock motors to TERMINALS 3 (LH), 2 (RH) to TERMINAL (B) 2 of the relay to TERMINAL (A) 7 to GROUND and the door lock motor causes the door to unlock.

3. IGNITION KEY REMINDER OPERATION
* Operating door lock knob (in door lock motor operation)
With ignition key in cylinder (Unlock warning SW ON), when any door is opened and locked using door lock knob (Door lock motor), all doors are locked once but each door is unlocked soon by the function of the integration relay. As a result, current flows from TERMINAL (B) 11 of the relay to TERMINAL (B) 3 to TERMINALS 7 (LH), 6 (RH) of the door lock motors to TERMINALS 3 (LH), 2 (RH) to TERMINAL (B) 2 of the relay to TERMINAL (A) 7 to GROUND and causes all the doors to unlock.

* Operating door lock control SW or door key lock and unlock SW
With ignition key in cylinder (Unlock warning SW on), when any door is opened and locked using the door lock control SW or door key lock and unlock SW, all doors are locked once but each door is unlocked by the function of the SW contained in motor, which inputs the signal to TERMINAL (B) 8 or (B) 7 of the integration relay. According to this input signal, current flows from TERMINAL (B) 11 of the relay to TERMINAL (B) 3 to TERMINALS 7 (LH), 6 (RH) of the door lock motors to TERMINALS 3 (LH), 2 (RH) to TERMINAL (B) 2 of the relay to TERMINAL (A) 7 to GROUND and causes all the doors to unlock.