Operation CHARM: Car repair manuals for everyone.

Air Conditioning Control

Air Conditioning Control Assembly:




COMPONENTS

REMOVAL

1. REMOVE COWL SIDE TRIMS
2. REMOVE LOWER NO.1 FINISH PANEL
3. REMOVE LOWER NO.1 FINISH RETAINER
4. REMOVE INSTRUMENT CLUSTER FINISH PANEL
5. REMOVE LOWER NO.2 FINISH PANEL
6. REMOVE GROVE COMPARTMENT
7. REMOVE CONTROL INSTRUMENT CLUSTER FINISH PANEL
8. REMOVE RADIO




9. DISCONNECT HEATER CONTROL CABLE

HINT:
At the time of installation, please refer to the following item.
After connection, adjust the control cables.




10. REMOVE A/C CONTROL ASSEMBLY
Remove the 2 screws and pulling out the A/C control assembly, then disconnect the connectors.

NOTE: Be careful not to bent the mode control cable, when pull out the A/C control assembly.

INSTALLATION

Installation is in the reverse order of removal (See page AC-124).

1. AFTER INSTALLATION, INSPECT HEATER CONTROL DIALS AND LEVER OPERATION
Turn the control lever and dials left and right then check that click sound can be heard and recoil is felt.
If click sound can not be heard or recoil is felt, proceed next step.

2. ADJUST HEATER CONTROL CABLES
a. Set A/C control assembly in these conditions.
1. Air inlet control lever at "RECIRC" position
2. Temperature control dial at "MAX. COOL" position
3. Mode control dial at "DEF" position




b. Adjust air inlet control cable.
1. Set air inlet damper control lever to "RECIRC" position.
2. Install inner cable to lever pin and clamp the outer cable.

HINT: Lock the clamp while lightly pushing the outer cable to the direction shown by an arrow in the illustration.




c. Adjust air mix control cable.
1. Set air mix damper control lever to "COOL" position.
2. Install inner cable to lever pin and clamp the outer cable.

HINT: Lock the clamp while lightly pulling the outer cable to the direction shown by an arrow in the illustration.




d. Adjust mode control cable.
1. Set mode control lever to "DEF" position.
2. Install inner cable to lever pin and clamp the outer cable.

HINT: Lock the clamp while lightly pushing the outer cable to the direction shown by an arrow in the illustration.




e. Adjust water valve control cable.
1. Set water valve control lever to "COOL" position.
2. Install inner cable to lever pin and clamp the outer cable.

HINT: Lock the clamp while lightly pulling the outer cable to the direction shown by an arrow in the illustration