Heated Oxygen Sensor
Heated Oxygen Sensor:
Heated Oxygen Sensor:
COMPONENTS
1. INSPECT HEATER RESISTANCE OF HEATED OXYGEN SENSOR
a. Disconnect the sensor connector.
b. Using an ohmmeter, measure the resistance between terminals +B and HT.
Resistance:
at 20°C (68°F) 11 - 16 ohms
at 800°C (1,472°F) 23 - 32 ohms
If the resistance is not as specified, replace the sensor.
Torque: 20 Nm (200 kg.cm, 14 ft.lb)
c. Reconnect the oxygen sensor connector.
2. Bank 1 Sensor 1:
INSPECT OPERATION OF HEATED OXYGEN SENSOR
3. Bank 1 Sensor 2:
INSPECT OPERATION OF HEATED OXYGEN SENSOR