Operation CHARM: Car repair manuals for everyone.

Power Window

P11 POWER WINDOW MASTER SW
7 - GROUND : Always approx. 12 volts
11 - GROUND : Approx. 12 volts with the ignition SW at ON or ST position Approx. 12 volts with key off power window operation
1 - GROUND : Always continuity
4 - GROUND : Continuity with power window master SW at MANUAL UP position Continuity with power window master SW at AUTO UP position
8 - GROUND : Continuity with power window master SW at MANUAL DOWN position Continuity with power window master SW at AUTO DOWN position

WINDOW LOCK SW
Open with the window lock SW at lock position