Heated Oxygen Sensor
HEATED OXYGEN SENSORINSPECTION
1. INSPECT HEATER RESISTANCE OF HEATED OXYGEN SENSOR (Bank 1 Sensor 2)
a. Disconnect the oxygen sensor connector.
Resistance:
b. Using an ohmmeter, measure the resistance between the terminals +B and HT.
If the resistance is not as specified, replace the sensor.
Torque: 20 N.m (200 kgf.cm, 14 ft.lbf)
c. Reconnect the oxygen sensor connector.
2. INSPECT OPERATION OF HEATED OXYGEN SENSORS