Heated Oxygen Sensor
INSPECTION1. INSPECT HEATER RESISTANCE OF HEATED OXYGEN SENSOR
a. Disconnect the sensor connector.
b. Using an ohmmeter, measure the resistance between terminals +B and HT.
If the resistance is not as specified, replace the sensor.
Torque: 20 N.m (200 kgf.cm, 14 ft.lbf)
c. Reconnect the oxygen sensor connector.
2. Bank 1 Sensor 2:
INSPECT OPERATION OF HEATED OXYGEN SENSOR