Combination Meter Disassembly and Assembly
COMBINATION METER ASSYOVERHAUL
1. REMOVE INSTRUMENT CLUSTER FINISH PANEL SUB-ASSY
a. Disengage the 7 clips.
b. Disconnect the connectors and remove the instrument cluster finish panel sub-assy.
2. REMOVE COMBINATION METER ASSY
a. Remove the 3 screws.
b. Loosen the 2 bolts and remove the combination meter assy.
3. REMOVE SPEEDOMETER GLASS
a. Remove the 2 screws.
b. Disengage the 6 claws and remove the speedometer glass.
4. REMOVE COMBINATION METER COVER NO.1
a. Remove the 10 screws and combination meter cover No.1.
5. REMOVE INCLINATION SENSOR ASSY
a. Remove the 2 screws and inclination sensor assy.
6. INSTALL COMBINATION METER ASSY
a. Pull the positions shown in the illustration in the arrow mark direction to make the check pins unseen form the surface.
b. Check that the connector on the instrument panel side is in place.
c. Install the combination meter assy with the 3 screws.
d. Tighten the screw shown in the illustration and check that the check pin protrudes.
7. INCLINATION SENSOR 0 ° CORRECTION
NOTE:
- When replacing or removing /installing the combination meter assy and inclination sensor assy, be sure to perform 0 ° correction of the inclination sensor.
- When performing 0 ° correction, install the combination meter assy and perform it In level surface.
- Also perform 0 ° correction when the body level setting is Inclined because of vehicle height adjustment.
a. Turn the ignition switch off.
b. While pressing the ido/trip switch, turn the ignition switch on.
c. Within 5 seconds after the ignition switch is turned on, repeat pressing and releasing the odo/trip switch 3 times and keep holding the last press for more than 5 seconds. (Buzzer sounds for a second)
NOTE: If the buzzer does not sound, perform this procedure from the first.
d. Release the odo/trip switch when buzzer sounds.
e. Press the odo/trip switch again and keep pressing for more than 5 seconds. (Buzzer sounds for a second again)
HINT:
- The buzzer sounds twice, reset operation is completed.
- The buzzer sound of the first and second time is same.
NOTE: If the buzzer does not sound or keep sounding for more than 1 second, perform the procedure from the first.