Actuator Check
LIST OF OPERATION METHODSBy operating each of the A/C control switches as shown in the diagram, it is possible to enter the diagnosis check mode.
ACTUATOR CHECK
a. After entering the DTC check mode (Sensor Check Mode), press the R/F switch.
b. Since each damper, motor and relay automatically operates at 1 sec. intervals beginning in order from 10 in the temperature display, check the temperature and air flow visually and by hand.
If slower display is desired, press the DEF switch and change it to the step operation. Each time the DEF switch is pressed, the display changes by 1 step.
HINT:
- Code are displayed in order from the smaller to the larger numbers.
- To cancel the check mode, press the OFF switch.