Operation CHARM: Car repair manuals for everyone.

Refrigerant: Testing and Inspection

ON-VEHICLE INSPECTION

1. INSPECT REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET

a. This method uses a manifold gauge set to locate problem areas. Read the manifold gauge pressure when these conditions are established.

Test conditions:
- Temperature at the air inlet is 30 to 35° C (86 to 95° F).
- Engine is running at 1,500 rpm.
- All doors are fully open.
- Blower speed control switch is at HI.
- Temperature control switch is at MAXCOOL.
- A/C switch is ON.




b. Gauge readings (Reference)







1. Normally functioning refrigeration system







2. The A/C system periodically changes between normal and improper function due to moisture in the refrigerant system.







3. The A/C system does not function effectively due to insufficient cooling.







4. The A/C system does not function effectively due to poor circulation of the refrigerant.







5. The A/C system does not function intermittently because the refrigerant does not circulate.







6. The A/C system does not function effectively due to overcharged refrigerant or insufficient cooling of the condenser.







7. The A/C system does not function due to air in the refrigeration system.

CAUTION: The Low-Pressure Piping May Be Very Hot And Cause Serious Burns.







8. The A/C system does not function effectively due to an expansion valve malfunction.







9. The A/C system does not function due to a defective compressor.




Gauge readings (Reference)