Variable Valve Timing Actuator Position Sensor: Testing and Inspection
ON-VEHICLE INSPECTION1. CHECK VVT SENSOR OUTPUT VOLTAGE
a. Turn the ignition switch to the ON position.
b. Check the voltage between the specified terminal and body ground.
c. While turning the crankshaft pulley by hand, measure the voltage between each terminal. Check that the voltage changes between the High range and Low range shown in the table below.