Variable Valve Timing Actuator Position Sensor: Service and Repair
REMOVAL1. REMOVE V-BANK COVER SUB-ASSEMBLY
2. REMOVE AIR CLEANER HOSE ASSEMBLY
3. REMOVE VVT SENSOR
a. Disconnect the 4 sensor connectors.
b. Remove the 4 bolts and 4 sensors.
INSTALLATION
1. INSTALL VVT SENSOR
a. Install the 4 sensors with the 4 bolts.
Torque: 10 N.m (102 kgf.cm, 7 ft.lbf)
b. Connect the 4 sensor connectors.
2. INSTALL AIR CLEANER HOSE ASSEMBLY
3. INSTALL V-BANK COVER SUB-ASSEMBLY