Skid Control ECU Communication Stop Mode
CAN COMMUNICATION SYSTEM: Skid Control ECU Communication Stop Mode
Skid Control ECU Communication Stop Mode
DESCRIPTION
WIRING DIAGRAM
INSPECTION PROCEDURE
PROCEDURE
1. CHECK CAN BUS LINE FOR DISCONNECTION (SKID CONTROL ECU SUB BUS LINE)
(a) Turn the ignition switch to the LOCK position.
(b) Disconnect the skid control ECU connector (S1).
(c) Measure the resistance according to the value(s) in the table below.
Standard resistance:
NG -- REPAIR OR REPLACE SKID CONTROL ECU BRANCH WIRE OR CONNECTOR (CAN-H, CAN-L)
OK -- Continue to next step.
2. CHECK WIRE HARNESS (IG, GND2)
(a) Measure the resistance according to the value(s) in the table below.
Standard resistance:
(b) Measure the voltage according to the value(s) in the table below.
Standard voltage:
NG -- REPAIR OR REPLACE WIRE HARNESS OR CONNECTOR
OK -- REPLACE MASTER CYLINDER SOLENOID