Installation
3UR-FE ENGINE CONTROL SYSTEM: KNOCK SENSOR:
INSTALLATION
1. INSTALL KNOCK SENSOR
(a) Install the 4 sensors with the 4 bolts so that the sensors are angled as shown in the illustration.
Torque: 20 Nm (204 kgf-cm, 15 ft-lbf)
NOTE: The acceptable installation angle of the sensor is between 10° upward and downward from the horizontal position.
(b) Connect the 4 sensor connectors.
2. INSTALL SEPARATOR CASE
(a) Install the separator case with the 4 bolts.
Torque: 10 Nm (102 kgf-cm, 7 ft-lbf)
3. INSTALL NO. 1 ENGINE COVER (Installation)
4. INSTALL NO. 2 CYLINDER HEAD COVER (Installation)
5. INSTALL INTAKE MANIFOLD
(a) Install the intake manifold (Installation).