Entire Combination Meter Does Not Operate
METER: METER / GAUGE SYSTEM: Entire Combination Meter does not Operate
Entire Combination Meter does not Operate
WIRING DIAGRAM
INSPECTION PROCEDURE
PROCEDURE
1. INSPECT FUSE
(a) Check the AM2 fuse in the engine room R/B.
Standard resistance:
Below 1 Ohms
(b) Check the GAUGE fuse in the driver side J/B.
Standard resistance:
Below 1 Ohms
(c) Check the DOME fuse in the engine room R/B.
Standard resistance:
Below 1 Ohms
NG -- REPLACE FUSE
OK -- Continue to next step.
2. INSPECT COMBINATION METER ASSEMBLY
(a) Disconnect the C10 connector.
(b) Measure the voltage according to the value(s) in the table below.
Standard voltage:
(c) Measure the resistance according to the value(s) in the table below.
Standard resistance:
NG -- REPAIR OR REPLACE HARNESS OR CONNECTOR
OK -- REPLACE COMBINATION METER ASSEMBLY