Operation CHARM: Car repair manuals for everyone.

Variable Valve Timing Actuator Position Sensor: Testing and Inspection








2UZ-FE ENGINE CONTROL SYSTEM: VVT SENSOR: INSPECTION

INSPECTION

1. INSPECT VVT SENSOR
(a) Using an ohmmeter, measure the resistance between the terminals.
Resistance:
Cold
835 to 1,400 Ohms
Hot
1,060 to 1,645 Ohms