Hazard Warning Switch: Testing and Inspection
LIGHTING: HAZARD WARNING SWITCH: INSPECTION
INSPECTION
1. INSPECT HAZARD WARNING SWITCH
(a) Check the resistance.
(1) Measure the resistance using an ohmmeter, and check the results in accordance with the value(s) in the table below.
Standard:
If the result is not as specified, replace the hazard warning signal switch assembly.
(b) Check the illumination operation.
(1) (1) Connect the battery positive (+) lead to terminal 11 and the battery negative (-) lead to terminal 10, then check that the illumination comes on.
Standard:
Illumination comes on.
If the illumination does not come on, replace the bulb.