Operation CHARM: Car repair manuals for everyone.

Shift Solenoid Valve





U151E AUTOMATIC TRANSAXLE: SHIFT SOLENOID VALVE: INSPECTION

1. INSPECT SHIFT SOLENOID VALVE SL3

(a) Measure the resistance according to the value(s) in the table below.





Standard resistance:





(b) If the value is not as specified, replace the shift solenoid valve.

(c) Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.

OK:

The solenoid valve makes an operating sound.

(d) If the result is not as specified, replace the shift solenoid valve.

2. INSPECT SHIFT SOLENOID VALVE SLT

(a) Measure the resistance according to the value(s) in the table below.





Standard resistance:





(b) If the value is not as specified, replace the shift solenoid valve.

(c) Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.

OK:

The solenoid valve makes an operating sound.

(d) If the result is not as specified, replace the shift solenoid valve.

3. INSPECT SHIFT SOLENOID VALVE S4

(a) Measure the resistance according to the value(s) in the table below.





Standard resistance:





(b) If the value is not as specified, replace the shift solenoid valve.

(c) Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body.

OK:

The solenoid valve makes an operating sound.

(d) If the result is not as specified, replace the shift solenoid valve.

4. INSPECT SHIFT SOLENOID VALVE SR

(a) Measure the resistance according to the value(s) in the table below.





Standard resistance:





(b) If the value is not as specified, replace the shift solenoid valve.

(c) Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body.

OK:

The solenoid valve makes an operating sound.

(d) If the result is not as specified, replace the shift solenoid valve.

5. INSPECT SHIFT SOLENOID VALVE DSL

(a) Measure the resistance according to the value(s) in the table below.





Standard resistance:





(b) If the value is not as specified, replace the shift solenoid valve.

(c) Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body.

OK:

The solenoid valve makes an operating sound.

(d) If the result is not as specified, replace the shift solenoid valve.

6. INSPECT SHIFT SOLENOID VALVE SL2

(a) Measure the resistance according to the value(s) in the table below.





Standard resistance:





(b) If the value is not as specified, replace the shift solenoid valve.

(c) Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.

OK:

The solenoid valve makes an operating sound.

(d) If the result is not as specified, replace the shift solenoid valve.

7. INSPECT SHIFT SOLENOID VALVE SL1

(a) Measure the resistance according to the value(s) in the table below.





Standard resistance:





(b) If the value is not as specified, replace the shift solenoid valve.

(c) Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.

OK:

The solenoid valve makes an operating sound.

(d) If the result is not as specified, replace the shift solenoid valve.