Accessory Meter Does Not Illuminate
METER / GAUGE / DISPLAY: METER / GAUGE SYSTEM: Accessory Meter does not Illuminate
- Accessory Meter does not Illuminate
DESCRIPTION
This circuit provides power to the accessory meter assembly.
WIRING DIAGRAM
INSPECTION PROCEDURE
PROCEDURE
1. CHECK ACCESSORY METER ASSEMBLY
(a) Check the type of accessory meter assembly malfunction.
Result
B -- CHECK HARNESS AND CONNECTOR (ACCESSORY METER ASSEMBLY - COMBINATION METER ASSEMBLY)
A -- Continue to next step.
2. CHECK HARNESS AND CONNECTOR (ACCESSORY METER ASSEMBLY CIRCUIT)
(a) Disconnect the G3 and G4 accessory meter connectors.
(b) Measure the voltage according to the value(s) in the table below.
Standard Voltage:
(c) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Text in Illustration
NG -- REPAIR OR REPLACE HARNESS OR CONNECTOR
OK -- REPLACE ACCESSORY METER ASSEMBLY Removal
3. CHECK HARNESS AND CONNECTOR (ACCESSORY METER ASSEMBLY - COMBINATION METER ASSEMBLY)
(a) Disconnect the F14 meter connector.
(b) Disconnect the G4 accessory meter connector.
(c) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
NG -- REPAIR OR REPLACE HARNESS OR CONNECTOR
OK -- Continue to next step.
4. REPLACE ACCESSORY METER ASSEMBLY
(a) Replace the accessory meter assembly with a new or normally functioning one Removal.
OK:
The operation of the accessory meter assembly returns to normal.
NG -- REPLACE COMBINATION METER ASSEMBLY Removal