P0711
A750E AUTOMATIC TRANSMISSION: AUTOMATIC TRANSMISSION SYSTEM: P0711: Transmission Fluid Temperature Sensor "A" Performance
P0711 - Transmission Fluid Temperature Sensor "A" Performance
DESCRIPTION
The ATF (Automatic Transmission Fluid) temperature sensor converts the fluid temperature into a resistance value which is input into the ECM.
The ECM applies a voltage to the temperature sensor through ECM terminal THO1.
The sensor resistance changes with the transmission fluid temperature. As the temperature becomes higher, the sensor resistance decreases.
One terminal of the sensor is grounded so that the sensor resistance and the voltage decrease as the temperature becomes higher.
The ECM calculates the fluid temperature based on the voltage signal.
MONITOR DESCRIPTION
This DTC indicates that there is a problem with the output from the ATF (Automatic Transmission Fluid) temperature sensor and that the sensor itself is defective. The ATF temperature sensor converts the ATF temperature to an electrical resistance value. Based on the resistance, the ECM determines the ATF temperature and detects any open or short malfunctions in the ATF temperature circuit or a fault of the ATF temperature sensor.
After running the vehicle for a certain period, the ATF temperature should increase. If the ATF temperature is below 20°C (68°F) after running the vehicle for a certain period, the ECM interprets this as a fault, and turns on the MIL.
When the ATF temperature is 95°C (203°F) or more and engine coolant temperature reaches 60°C (140°F) after cold start, the ECM also determines this as a fault, turns on the MIL, and stores the DTC.
MONITOR STRATEGY
TYPICAL ENABLING CONDITIONS
All
Condition (A)
Condition (B)
TYPICAL MALFUNCTION THRESHOLDS
Either of the following conditions is met: Condition (A) or (B).
Condition (A)
Condition (B)
COMPONENT OPERATING RANGE
WIRING DIAGRAM
INSPECTION PROCEDURE
NOTICE:
Perform the universal trip to clear permanent DTCs Reading and Clearing Diagnostic Trouble Codes.
HINT
According to the Data List displayed on a Techstream, you can read the values of components, such as the switches, sensors and actuators, without removing any parts. Reading the Data List as a first step of troubleshooting is one method of shortening labor time.
NOTICE:
In the table below, the values listed under "Normal Condition" are for reference only. Do not depend solely on these reference values when judging whether a part is faulty or not.
1. Warm up the engine.
2. Turn the ignition switch off.
3. Connect the Techstream to the DLC3.
4. Turn the ignition switch to ON.
5. Turn the Techstream on.
6. Enter the following menus: Powertrain / Engine and ECT / Data List / All Data.
7. According to the display on the Techstream, read the Data List.
Engine and ECT
HINT
When DTC P0712 is output and Techstream reading is 150°C (302°F) or more, there is a short circuit.
When DTC P0713 is output and Techstream reading is -40°C (-40°F), there is an open circuit.
Measure the resistance between terminal THO1 and the body ground.
HINT
If a circuit related to the ATF temperature sensor becomes open, P0713 is immediately set (in 0.5 seconds). When P0713 is set, P0711 cannot be detected.
It is not necessary to inspect the circuit when P0711 is set.
PROCEDURE
1. CHECK ANY OTHER DTCS OUTPUT (IN ADDITION TO DTC P0711)
(a) Connect the Techstream to the DLC3.
(b) Turn the ignition switch to ON.
(c) Turn the Techstream on.
(d) Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.
(e) Read the DTCs using the Techstream.
Result
HINT
If any codes besides P0711 are output, perform troubleshooting for those DTCs first.
B -- GO TO DTC CHART Automatic Transmission System - A750E
A -- Continue to next step.
2. CHECK TRANSMISSION FLUID LEVEL
(a) Check the transmission fluid level Procedures.
OK:
Automatic transmission fluid level is correct.
NG -- ADD FLUID
OK -- REPLACE TRANSMISSION WIRE (ATF TEMPERATURE SENSOR) Removal