Alternator: Testing and Inspection
1GR-FE CHARGING: GENERATOR: INSPECTION
1. INSPECT GENERATOR CLUTCH PULLEY
(a) Hold the center of the generator clutch pulley and check that the outer ring turns counterclockwise and does not turn clockwise.
Text in Illustration
If the result is not as specified, replace the generator clutch pulley.
2. INSPECT GENERATOR BRUSH HOLDER ASSEMBLY
(a) Using a vernier caliper, measure the brush length.
Text in Illustration
Standard exposed length:
9.5 to 11.5 mm (0.374 to 0.453 in.)
Minimum exposed length:
4.5 mm (0.177 in.)
If the brush length is less than the minimum, replace the generator brush holder assembly.
3. INSPECT GENERATOR ROTOR ASSEMBLY
(a) Check that the generator rotor bearing is not rough or worn.
If necessary, replace the generator rotor assembly.
(b) Check the generator rotor for an open circuit.
(1) Measure the resistance according to the value(s) in the table below.
Text in Illustration
Standard Resistance:
If the result is not as specified, replace the generator rotor assembly.
(c) Check if the generator rotor is grounded.
(1) Measure the resistance according to the value(s) in the table below.
Text in Illustration
Standard Resistance:
If the result is not as specified, replace the generator rotor assembly.
(d) Using a vernier caliper, measure the slip ring diameter.
Text in Illustration
Standard diameter:
14.2 to 14.4 mm (0.559 to 0.567 in.)
Minimum diameter:
14.0 mm (0.551 in.)
If the diameter is less than the minimum, replace the generator rotor assembly.
4. INSPECT GENERATOR DRIVE END FRAME BEARING
(a) Check that the drive end frame bearing is not rough or worn.
If necessary, replace the generator drive end frame bearing.