Entire Combination Meter Does Not Operate
METER: METER / GAUGE SYSTEM: Entire Combination Meter does not Operate
- Entire Combination Meter does not Operate
DESCRIPTION
This circuit provides power to the combination meter assembly.
WIRING DIAGRAM
INSPECTION PROCEDURE
NOTICE:
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
PROCEDURE
1. CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - BATTERY AND BODY GROUND)
(a) Disconnect the E13 combination meter assembly connector.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
(c) Measure the voltage according to the value(s) in the table below.
Standard Voltage:
Text in Illustration
(d) Reconnect the combination meter connector.
NG -- REPAIR OR REPLACE HARNESS OR CONNECTOR
OK -- REPLACE COMBINATION METER ASSEMBLY Removal