Installation
U151E AUTOMATIC TRANSAXLE: SPEED SENSOR: INSTALLATION
1. INSTALL SPEED SENSOR (NC SENSOR)
(a) Coat a new O-ring with ATF.
(b) Install the speed sensor with the bolt.
Torque : 11 Nm (112 kgf-cm, 8 ft-lbf)
HINT
Make sure to install the same manufacturer's sensor.
(c) Connect the speed sensor connector.
2. INSTALL SPEED SENSOR (NT SENSOR)
(a) Coat a new O-ring with ATF.
(b) Install the speed sensor with the bolt.
Torque : 11 Nm (112 kgf-cm, 8 ft-lbf)
HINT
Make sure to install the same manufacturer's sensor.
(c) Connect the speed sensor connector.
3. INSTALL AIR CLEANER BRACKET Installation
4. INSTALL AIR CLEANER CASE SUB-ASSEMBLY Installation
5. REMOVE AIR CLEANER FILTER ELEMENT SUB-ASSEMBLY
6. INSTALL AIR CLEANER CAP SUB-ASSEMBLY Installation
7. INSTALL NO. 1 AIR CLEANER INLET Installation
8. INSTALL NO. 2 AIR CLEANER INLET Installation
9. INSTALL COOL AIR INTAKE DUCT SEAL Installation
10. INSTALL BATTERY Installation
11. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
NOTICE:
When disconnecting the cable, some systems need to be initialized after the cable is reconnected Repair Instruction - Initialization.