Operation CHARM: Car repair manuals for everyone.

Air Conditioning System (for Manual Air Conditioning System)





AIR CONDITIONING: AIR CONDITIONING SYSTEM (for Manual Air Conditioning System): B1411/11: Room Temperature Sensor Circuit
B1411/11 - Room Temperature Sensor Circuit

DESCRIPTION

The room temperature sensor is installed in the instrument panel to detect the cabin temperature. The resistance of the room temperature sensor changes in accordance with the cabin temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.

The air conditioning amplifier applies a voltage (5 V) to the room temperature sensor and reads voltage changes as changes in the resistance of the room temperature sensor.





WIRING DIAGRAM





INSPECTION PROCEDURE

PROCEDURE

1. INSPECT ROOM TEMPERATURE SENSOR

(a) Remove the room temperature sensor (for front) Removal.





(b) Measure the resistance according to the value(s) in the table below.

Standard resistance:





NOTICE:
* Touching the sensor even slightly may change the resistance value. Be sure to hold the connector of the sensor.
* When measuring, the sensor temperature must be the same as the ambient temperature.

HINT
As the temperature increases, the resistance decreases (see the graph).

NG -- REPLACE ROOM TEMPERATURE SENSOR Removal
OK -- Continue to next step.

2. CHECK HARNESS AND CONNECTOR (ROOM TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER)

(a) Disconnect the D26 sensor connector.





(b) Disconnect the D37 amplifier connector.

(c) Measure the resistance according to the value(s) in the table below.

Standard resistance:





NG -- REPAIR OR REPLACE HARNESS OR CONNECTOR

OK -- REPLACE AIR CONDITIONING AMPLIFIER Removal