Power Meter Gauge Malfunction
METER: METER / GAUGE SYSTEM: Power Meter Gauge Malfunction
- Power Meter Gauge Malfunction
WIRING DIAGRAM
INSPECTION PROCEDURE
PROCEDURE
1. CHECK CAN COMMUNICATION SYSTEM
(a) Check for the DTC.
w/ Smart Key System: Diagnosis System
w/o Smart Key System: Diagnosis System
Result
D -- GO TO HYBRID CONTROL SYSTEM How To Proceed With Troubleshooting
C -- GO TO CAN COMMUNICATION SYSTEM How to Proceed With Troubleshooting
B -- GO TO CAN COMMUNICATION SYSTEM How to Proceed With Troubleshooting
A -- Continue to next step.
2. PERFORM ACTIVE TEST USING TECHSTREAM (POWER METER)
(a) Connect the Techstream to the DLC3.
(b) Turn the ignition switch to ON.
(c) Turn the Techstream on.
(d) Enter following menus: Body Electrical / Combination Meter / Active Test.
(e) Check the operation by referring to the table below.
Combination Meter:
OK:
Needle indication is normal.
NG -- REPLACE COMBINATION METER ASSEMBLY Removal
OK -- GO TO HYBRID CONTROL SYSTEM Hybrid Control System