Removal
2GR-FXE CHARGING: BATTERY: REMOVAL
1. REMOVE DECK BOARD ASSEMBLY Removal
2. REMOVE BATTERY SERVICE HOLE COVER ASSEMBLY Removal
3. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
NOTICE:
When disconnecting the cable, some systems need to be initialized after the cable is reconnected Repair Instruction - Initialization.
4. REMOVE AUXILIARY BATTERY
(a) Open the battery terminal cap.
(b) Loosen the nut and disconnect the positive (+) battery terminal.
(c) Remove the nut.
(d) Remove the battery clamp.
(e) Disconnect the battery ventilation hose.
(f) Remove the battery insulator.
(g) Remove the battery.