Operation CHARM: Car repair manuals for everyone.

Entire Combination Meter Does Not Operate





METER / GAUGE / DISPLAY: METER / GAUGE SYSTEM: Entire Combination Meter does not Operate
- Entire Combination Meter does not Operate

DESCRIPTION

This circuit is the power source circuit for the combination meter. This circuit provides 2 power source types: one is a constant power source mainly used as a backup power source, and other is a power source mainly used for signal transmission. The constant power source is mainly used as a backup power source of the meter CPU. However, it is also used for communication. If a voltage of 12 V is not applied to terminal IG+ when the ignition switch is ON, the indicator will not operate.

WIRING DIAGRAM





INSPECTION PROCEDURE

PROCEDURE

1. INSPECT FUSE (MET, MET-B)

(a) Remove the MET and MET-B fuses from the engine room relay block.





(b) Measure the resistance according to the value(s) in the table below.

Standard Resistance:





NG -- CHECK FOR SHORTS IN ALL HARNESSES AND CONNECTORS CONNECTED TO FUSE AND REPLACE FUSE
OK -- Continue to next step.

2. CHECK HARNESS AND CONNECTOR (COMBINATION METER - BATTERY AND BODY GROUND)

(a) Disconnect the H37 meter connector.





(b) Measure the resistance and voltage according to the value(s) in the table below.

Standard Resistance:





Standard Voltage:





NG -- REPAIR OR REPLACE HARNESS OR CONNECTOR

OK -- REPLACE COMBINATION METER ASSEMBLY Removal