Installation
2GR-FE ENGINE CONTROL: KNOCK SENSOR: INSTALLATION
1. INSTALL KNOCK SENSOR
(a) Install the 2 knock sensors with the 2 bolts as shown in the illustration.
Text in Illustration
Torque : 20 Nm (204 kgf-cm, 15 ft-lbf)
NOTICE:
Make sure that each knock control sensor is in the correct position.
(b) Connect the 2 knock sensor connectors.
2. INSTALL INTAKE MANIFOLD
Installation