Diagnosis System
WINDOW / GLASS: WINDOW DEFOGGER SYSTEM: DIAGNOSIS SYSTEM
1. CHECK DLC3
(a) Check the DLC3 General Information.
2. INSPECT BATTERY VOLTAGE
(a) Measure the battery voltage.
Standard voltage:
11 to 14 V
If the voltage is below 11 V, recharge or replace the battery.