Installation
2TR-FE EMISSION CONTROL: AIR FUEL RATIO SENSOR: INSTALLATION
1. INSTALL AIR FUEL RATIO SENSOR
(a) Using SST, install the air fuel ratio sensor.
SST : 09224-00010
Torque : 44 Nm (449 kgf-cm, 33 ft-lbf)
Torque : 40 Nm (408 kgf-cm, 30 ft-lbf) with SST
NOTICE:
Use a torque wrench with a fulcrum length of 300 mm (11.81 in.).
(b) Connect the wire harness clamp.
(c) Connect the air fuel ratio sensor connector.
2. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
Torque : 3.9 Nm (40 kgf-cm, 35 in-lbf)