CAN Bus Line
CAN COMMUNICATION: CAN COMMUNICATION SYSTEM: CAN Bus Line
- CAN Bus Line
DESCRIPTION
When any DTC of the CAN communication system is output, first measure the resistance between the terminals of the DLC3 and the yaw rate sensor connector to specify the trouble area.
WIRING DIAGRAM
INSPECTION PROCEDURE
PROCEDURE
1. CHECK CAN BUS WIRE (MAIN BUS LINE FOR DISCONNECTION, BUS LINES FOR SHORT CIRCUIT)
(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
NG-B -- CHECK CAN BUS WIRE (FOR SHORT CIRCUIT) Short in CAN Bus Lines
NG-A -- CHECK CAN BUS MAIN WIRE (FOR DISCONNECTION) CAN Main Bus Line for Disconnection
OK -- Continue to next step.
2. CHECK CAN BUS WIRE (FOR SHORT TO +B)
(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
NG -- CHECK CAN BUS WIRE (FOR SHORT TO +B) Short to B+ in CAN Bus Line
OK -- Continue to next step.
3. CHECK CAN BUS WIRE (FOR SHORT TO GND)
(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
NG -- CHECK CAN BUS WIRE (FOR SHORT TO GND) Short to GND in CAN Bus Line
OK -- GO TO HOW TO PROCEED WITH TROUBLESHOOTING How to Proceed With Troubleshooting