Installation
1GR-FE EMISSION CONTROL: HEATED OXYGEN SENSOR: INSTALLATION
1. INSTALL HEATED OXYGEN SENSOR
(a) Using SST, install the 2 heated oxygen sensors onto the exhaust pipe.
SST : 09224-00010
Torque : 44 Nm (449 kgf-cm, 33 ft-lbf)
(b) Connect the 2 heated oxygen sensor connectors.
2. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
Torque : 3.9 Nm (40 kgf-cm, 35 in-lbf)
3. CHECK FOR EXHAUST GAS LEAKAGE