Removal
3UR-FE ENGINE CONTROL SYSTEM: ECM: REMOVAL
1. DISCONNECT CONNECTOR HOLDER BLOCK
(a) Remove the 3 bolts and move the connector holder block so that the ECM can be removed in the next step.
2. REMOVE ECM
(a) Raise the 2 levers while pushing the locks on the 2 levers.
NOTICE:
Make sure that the lock lever is raised 90° as shown in the illustration before disconnecting the connectors. Failure to do this may cause the connectors to break.
(b) Disconnect the 2 connectors.
(c) Remove the 4 bolts and ECM.
3. REMOVE GASKET
(a) Peel off the rubber part of the gasket.
(b) Spray gasket remover or equivalent on the remaining tape of the gasket.
NOTICE:
When using gasket remover or equivalent, cover the ECM connector with a cloth.
(c) Remove the tape of the gasket without using bladed objects.