Automatic Running Board System
EXTERIOR PANELS / TRIM: AUTOMATIC RUNNING BOARD SYSTEM: 11,12: Short in Motor LH
12 - Short in Motor RH
DESCRIPTION
When there is a short in the side auto step motor circuit, the side auto step controller ECU assembly halts the operation of the automatic running board.
WIRING DIAGRAM
INSPECTION PROCEDURE
PROCEDURE
1. CHECK HARNESS AND CONNECTOR (SIDE AUTO STEP MOTOR - SIDE AUTO STEP CONTROLLER ECU)
(a) Disconnect the O25*1 or N23*2 side auto step motor assembly connector.
* *1: for LH
* *2: for RH
(b) Disconnect the A42 side auto step controller ECU assembly connector.
(c) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
for LH
for RH
NG -- REPAIR OR REPLACE HARNESS OR CONNECTOR
OK -- REPLACE SIDE AUTO STEP MOTOR ASSEMBLY Removal