Inspection
1GR-FE ENGINE CONTROL: CAMSHAFT OIL CONTROL VALVE: INSPECTION
1. INSPECT CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY
(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
If the result is not as specified, replace the camshaft timing oil control valve.
(b) Connect the positive (+) lead of the battery to terminal 1 and the negative (-) lead to terminal 2 and check the movement of the valve.
OK:
If the result is not as specified, replace the camshaft timing oil control valve.
If the valve cannot return properly because of foreign matter, a small pressure leak in the advanced direction may occur and a DTC may be stored.