Inspection
1AR-FE ENGINE CONTROL SYSTEM: CAMSHAFT OIL CONTROL VALVE: INSPECTION
1. INSPECT CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY
(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
If the result is not as specified, replace the oil control valve assembly.
(b) Connect a battery positive (+) lead to terminal 1 and negative (-) lead to terminal 2, and check the movement of the valve.
OK:
Please confirm direction of movement in the event of a leak.