Pressures, Checking
A/C Refrigerant System Pressures, Checking
Check A/C refrigerant system pressures using these three tests:
1 - Air temperature drop from center instrument panel outlet (A/C system cooling performance)
2 - A/C system high pressure
3 - A/C system low pressure
Combined results of these tests determines A/C system component malfunction.
Test 1: Air temperature drop from center instrument panel outlet, checking (A/C system cooling performance)
- Start engine.
- Set temperature control to maximum "cold" Manual A/C) or "LO" (if Climatronic).
- Manual A/C: press "A/C" button and select second blower speed.
- Climatronic: Select minimum blower speed (manual override) by pressing "decrease blower speed" button (observe front "blower speed" display in control head)
- Adjust air distribution to instrument panel outlets.
- Insert thermometer into center instrument panel outlet and raise engine speed to approximately 1500 RPM.
Specified result
With humidity normal and outside (ambient) temperature between 20 - 25 °C (68 - 77 °F), system is cooling satisfactorily if air temperature from center instrument panel vent drops below 10 °C (50 °F) within 1 minute.
For higher ambient temperatures and/or higher humidity, specified air temperature from center instrument panel vent can be slightly higher.
If specified reading is not obtained, perform tests 2 and 3, then compare results of all three tests See table.
Test 2: A/C system high pressure, checking
- Connect high- and low-pressure hoses of refrigerant recovery/recycling/recharging unit Kent-Moore ACR4 or equivalent, to high- and low-pressure service valves.
- Disconnect electrical connector from coolant fan.
- Start engine.
- Set temperature control to maximum "hot" (if Manual A/C) or "HI" (if Climatronic).
- Manual A/C: press "A/C" button and select highest blower speed.
- Adjust air distribution to footwell outlets.
- Raise engine speed to approximately 1500 RPM.
Specified result
System high pressure is normal if high-pressure gauge reads 232 psi (16 bar) within 30 seconds.
If specified reading is not obtained, also perform test 3 and compare results of all three tests table.
Test 3: A/C system low pressure, checking
- Connect high- and low-pressure hoses of refrigerant recovery/recyling/recharging unit Kent-Moore ACR4, or equivalent, to high- and low-pressure service valves.
- Start engine.
- Set temperature control to maximum "cold" (if Manual A/C) or "LO" (if Climatronic).
- Manual A/C: press "A/C" button and select first blower speed.
- Climatronic: Reduce blower speed to lowest setting (manual override) by pressing "decrease blower speed" button (observe front "blower speed" display in control head).
- Adjust air distribution to instrument panel outlets.
- Raise engine speed to 1500 RPM.
Specified result
System low pressure is normal if low-pressure gauge reads 22 - 36 psi (1.5 - 2.5 bar) within 30 seconds.