Read Measuring Value Block (Function 08)
Read Measuring Value Block (Function 08)
The measuring value block is divided into 6 display groups, each containing 4 display fields.
Use this function to observe various radio system inputs.
- Connect VAG 1551 Scan Tool (ST), input address word 56 "Radio" and then press ->button, until "Select function XX" is shown in display.
Indicated on display:
Rapid data transfer HELP
Select function XX
- Press buttons -0- and -8- to select function 08, "Read measuring value block".
Indicated on display:
Rapid data transfer Q
08 - Read measuring value block
- Press -Q- button to confirm input
Indicated on display:
Read measuring value block Q
Enter display group number XX
- Enter desired display group number and press -Q- button to confirm input.
Indicated on display:
Read measuring value block X ->
1 2 3 4
NOTE:
- Interpreting measured values in display fields.
- With printer switched on, information in display is printed out.
- Press -> button if measured value specifications are met in all display fields.
Table of selectable display group numbers
Part 1:
Part 2:
NOTE: After ending function 08 Read Measuring Value Block, check DTC memory (function 02).