Fuel Distance/Mileage Module: Service and Repair
Adaptation (function 10)
Use this function to initiate and store the following changes:
- Adaptation of odometer reading when replacing/exchanging instrument cluster
- Adaptation of fuel gauge reading
- Adaptation of MFI fuel consumption indicator (where applicable)
Individual functions are called up using the appropriate channel number from adaptation table.
Adaptation table:
Adaptation channel Adaptation functions
03 Fuel consumption indicator adaptation (where applicable)
09 Odometer adaptation
16 Distance impulse number (K number):Read only.Cannot be changed
30 Fuel gauge, checking (adaptation)
NOTE: After changing an adaption value or ending an adaption channel the function "10- Adaption" must be performed to select another adaption channel!
Fuel consumption display, adaptation
NOTE:
- Consumption indicator can only be adapted once between 85% and 115%.
- Value must be entered in steps of 5%.
- Connect VAG 1551 Scan Tool (ST), select operating mode 1 "Rapid data transfer", switch ignition on and enter address word 17 for "instrument cluster".
After control module identification is displayed:
- Press -> button.
Indicated on display:
Rapid data transfer HELP
Select function XX
- Press buttons -1- and -0- to select function 10 "Adaptation
Indicated on display:
Rapid data transfer Q
10 - Adaptation
- Press -Q- button to confirm input.
Indicated on display:
Adaptation
Enter channel number XX
- Press buttons -0- and -3-.
- Press -Q- button to confirm input.
Indicated on display:
Channel 03 adaptation 100 ->
(-1 3-)
- Press the -> button to continue.
NOTE: Correction of fuel consumption display is only possible via direct input.
Indicated on display:
Channel 03 adaptation 100
Enter adaptation value XXXXX
- Input desired correction value using scan tool keypad, filling initial positions with "0".
Example:
Desired input value: 90% Keypad input: 00090
Indicated on display:
Channel 03 adaptation 100 Q
Enter adaptation value 00090
- Press -Q- button to confirm input.
Indicated on display:
Channel 03 adaptation 90 Q
(-1 3-)
- Press -Q- button to confirm input.
Indicated on display:
Channel 03 adaptation 90 Q
Store modified value?
- Press -Q- button to confirm input.
Indicated on display:
Channel 03 adaptation 90 ->
Modified value has been stored
- Conclude adaptation of the consumption indicator by pressing the -> button.
Indicated on display:
Rapid data transfer HELP
Select function XX
NOTE: If input is incorrect, tester switches to function mode.
If displayed:
Function is unknown or can ->
not be performed at the moment
- Press -> button.
- Select "Adaptation" function 10 again and select adaptation channel 03.
- Repeat correction of the consumption indicator and press -Q- button to confirm input.