Reading
Read Measuring Value Block (Function 08)
- Connect VAG 1551 Scan Tool (ST) and enter address word -02- for "Transmission Electronics". Advance VAG 1551 Scan Tool (ST) program until "Select function XX" is indicated on display. Scan Tool Connecting and Initial Checks
Indicated on display:
Rapid data transfer HELP
Select function XX
- Press keys -0- and -8-. (To select function 08 "Reading measured value block".)
Indicated on display:
Rapid data transfer Q
08 - Reading measured value block
- Press -Q- key to confirm entry.
Indicated on display:
Reading measured value block
Enter display group number XX
List of selectable display group numbers
Display Group 01 - 05:
Indicated on display:
Reading measured value block 1 ->
1 2 3 4
(Specification) Measured Value Blocks Test Table
- There are always 4 display fields in the measured value block (displayed in physical units, if necessary.)
NOTE:
- Explanation of values in the individual display fields. Measured Value Blocks Test Table
- If the printer is turned ON, the current display is printed out on the log.
- If the specified values of the Throttle Position (TP) Sensor are not reached in display field -2-, the system should first be restored to the basic setting. Basic Setting (Function 04)
- If the values in all display fields are as specified:
- Press -> key.
Indicated on display:
Rapid data transfer HELP
Select function XX